A wood stove and a rack of firewood inside a dark log cabin

Prefab Fireplace Repair from Glendora, Part by Listed Part

Ask About a Prefab Fireplace

Address, wood or gas, and what it is doing. We call back to set the visit.

Price in writing firstParts matched to model
Parts Ordered by Model
Written Price Before Work
Photos in Every Report
Prefab and Brick Chimneys
Based in Glendora
Parts Ordered by Model
Written Price Before Work
Photos in Every Report
Prefab and Brick Chimneys
Based in Glendora
Services for Metal and Brick Fireplaces

From a cracked back panel to a new chase top, matched to the model.

Every service below begins with the plate on the fireplace and ends with photos and a written price for anything further.

01

Chimney Sweep

Flue and firebox brushed with heads that will not score a metal chimney, plus a parts check on the way out.

Brush heads sized to round metal pipe
Firebox sealed off and vacuumed while we work
Refractory panels checked for cracks and gaps
Termination cap and chase top seen from the roof
Read what this covers
02

Chimney Inspection

A Level 1 look at the firebox, panels, pipe joints and top, with the listing plate read and recorded.

Listing plate located and model recorded
Panels, screen, doors and hearth checked
Pipe joints and spacers inspected where visible
Chase top and cap seen from the roof
Read what this covers
03

Chimney Repair

Repairs to metal pipe, chase tops, caps and brick stacks, each priced in writing before a tool comes out.

Rusted or separated pipe sections replaced
Firestop spacers and attic shields refitted
Chase walls opened where water got in
Brick, mortar and crown work on masonry stacks
Read what this covers
04

Fireplace Inspection

The firebox, panels, screen, doors and gas or wood parts of a prefab unit, checked against its maker's listing.

Back and side refractory panels checked for cracks
Doors, screen and grate matched to the model
Mantel and trim clearances measured
Listing plate found and photographed
Read what this covers
05

Fireplace Repair

Prefab fireboxes repaired with the panels, grates, doors and parts the maker lists for that model number.

Refractory panels ordered by model number
Damper handles, blades and linkage replaced
Door kits and screens that fit the opening
Blower kits on units built to take them
Read what this covers
06

Chimney Level 2 Inspection

Video of every pipe joint from firebox to cap, plus the attic and chase, for a sale or after a quake.

Video of each pipe joint and seam
Firestops at ceiling and roof checked
Chase framing looked at for water and heat marks
Listing plate and model recorded
Read what this covers
07

Chimney Cap Installation

Termination caps matched to the pipe brand on metal chimneys, or a mesh cap fixed to a brick flue.

Pipe brand and diameter read before ordering
Listed termination caps for metal chimneys
Mesh caps on clay flue tile
Rusted or wind-bent caps taken off
Read what this covers
08

Chimney Flashing Repair

Water stopped where a brick stack or a framed chase meets the roof, with the leak point shown in photos.

Leak point traced from roof and attic
Step and counter flashing renewed
Chase siding lapped over the flashing
Crickets on the high side of wide chases
Read what this covers
09

Chimney Masonry Repair

Mortar joints, broken brick and cracked crowns on the brick stacks that older houses still carry.

Open joints raked and repointed
Spalled or loose brick replaced
Mortar matched to the brick
Crowns recast with an overhang
Read what this covers
10

Chimney Rebuilds

Brick stacks rebuilt above the roof, or replaced with a framed chase around a listed metal chimney.

Rebuild in brick above the roof
Framed chase with a listed metal chimney
Permit pulled and inspections booked
New liner or pipe fitted in the rebuild
Read what this covers
11

Fireplace Cleaning

Soot, ash and smoke film cleared from a metal firebox, its panels, its glass doors and its screen.

Panels cleaned by hand, not scraped
Glass doors cleared of soot film
Screen and grate brushed down
Face and hearth wiped where the finish allows
Read what this covers
12

Gas Fireplace Cleaning

Burner, pilot, logs, glass and vent of a gas fireplace serviced to the maker's manual for that model.

Burner ports and pilot hood cleared
Logs placed to the manual's diagram
Glass lifted out, cleaned and refitted
Flame pattern watched after relighting
Read what this covers
13

Gas Fireplace Repair

Pilots, thermocouples, valves, switches and remotes on gas fireplaces, tested in order and fixed with model parts.

Gas supply and pilot checked first
Thermocouples and thermopiles replaced
Igniters, switches and receivers tested
Valves replaced with the model's part
Read what this covers
14

Fireplace Remodel

A new surround, mantel or face around a prefab unit, kept inside the clearances on its listing.

Clearances taken from the listing first
Tile, stone or plaster surrounds
Mantel height set to the manual
Air openings on the face kept clear
Read what this covers
15

Fireplace Inserts

Gas inserts approved for a factory-built firebox or a brick fireplace, fitted with a vent of their own.

Insert listing checked against the firebox
Coaxial or co-linear vent kit fitted
Gas line connected and leak tested
Old grate and panels handled as the manual says
Read what this covers
16

Pellet Stove Repair

Pellet stoves that will not light, run lean or keep shutting down, traced to the failed part and fixed.

Fault history read off the board
Igniter element tested and replaced
Feed motor and fans checked
Vacuum and door switches tested
Read what this covers
17

Wood Stove Repair

Door gaskets, baffles, firebrick and stovepipe on freestanding wood stoves, with clearances measured each visit.

Rope gaskets on doors and glass
Baffle boards and firebrick replaced
Stovepipe seams and joints checked
Hearth pad and wall clearances measured
Read what this covers
18

Gas Logs

Log sets for wood-burning prefab units whose manual allows them, with the gas line run and tested.

Manual checked for log approval
Burner matched to box width and depth
Gas line run and leak tested
Damper held open for vented sets
Read what this covers
19

Chimney Seismic Retrofit

Brick stacks braced, strapped, or cut down and topped with a lighter framed chase, each option priced in writing.

Brick stack checked for cracks and lean
Steel bracing to the roof framing
Straps at floor and ceiling lines
Upper brick replaced with a framed chase
Read what this covers
20

Chimney Crown Repair

Cracked mortar crowns on brick stacks sealed or recast; on a framed chase, the steel top does that job instead.

Crown cracks measured and photographed
Sealant on thin, stable cracks
Split crowns broken out and repoured
Gap left around the flue tile
Read what this covers
21

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, with the hood flap checked.

Duct cleared end to end
Transition hose checked for kinks
Outside hood flap opened and cleared
Roof terminations reached from the roof
Read what this covers
22

Chimney Liner Installation

Stainless liners for brick flues and for inserts, sized from the appliance's vent rating and the flue's inside measure.

Flue measured on the inside
Liner size taken from the appliance
Stainless liner run from connection to top
Insulated liners where brick sits close to wood
Read what this covers
23

Chimney Leak Repair

Water coming in at a chimney or chase traced to its entry point, then stopped and photographed.

Water traced from roof and attic
Chase tops, siding and flashing checked
Brick joints and crowns tested
Price set once the cause is found
Read what this covers
24

Chimney Waterproofing

A breathable water repellent on brick, applied after joints and crown are fixed, never in place of them.

Brick checked for open joints first
Vapor-permeable repellent applied
Crown and flashing fixed before sealing
Chase siding and paint looked over
Read what this covers
25

Chimney Damper Repair

Prefab damper blades, handles and linkages fixed with the maker's kit; brick fireplaces get throat or top dampers.

Damper kits ordered by model
Handles, chains and linkages refitted
Rusted throat dampers repaired
Top-mounted dampers on a cable control
Read what this covers
26

Chimney Chase Cover

Rusted or pooling chase tops replaced in heavier stainless or galvanized steel, cut to the chase and the pipe.

Chase and pipe opening measured
Tops made in heavier steel
Cross break to shed water
Termination cap refitted
Read what this covers
Brick fireplace below a TV in a living room with a vaulted ceiling

Listed Parts

Read the plate, order to the model, fit it as the manual shows.

From Glendora

Metal fireboxes, framed chases, and the parts that belong in them.

Tully Chimney Works works out of Glendora, where many houses from the 1970s on were built with a factory-built fireplace in a framed chase. We read the plate, order the listed parts, and put every price in writing first.

A factory-built fireplace was approved as a set of matching parts. When a panel cracks or a chase top rusts through, the fix that keeps that approval is the maker's own part, so the plate is where every job begins.

Brick chimneys on older foothill houses get masonry repair instead. Either way the report names what we saw, shows it in photos, and prices each repair before anything is ordered.

Unsafe units named on page one

Arrival window agreed when you book

Model number on every report

Repairs wait for your written yes

Discontinued Models

No part left? You get the options in writing.

A listed insert, a new unit in the same opening, or retiring the fireplace, each with its price.

The Plate Decides

Each repair starts with the maker, model and listing on the plate inside the fireplace. Parts are ordered to match it, not to whatever happens to fit.

Unsafe Is Said Plainly

If a fireplace should not be used, the report says so on page one, and you hear it from the technician before we leave the house.

Prices on Paper

Jobs with a published price cost what this site says. Everything else is priced in writing and waits for your yes.

Glendora Based

We work out of Glendora, with Azusa, Covina and Claremont on the same route and the other foothill towns close behind.

Factory-Built Fireplaces

What Glendora owners ask about metal fireplaces

Listing plates, panel repairs, inspection levels and no-burn days. Not covered here? Ask through the contact page.

Look inside the opening. A metal firebox lined with flat panels that only look like brick, a mesh screen on a rod, and slots or louvers above or below the opening all point to a prefab unit. Somewhere near the opening, often behind the lower grille, there is a plate naming the maker and model. On the roof, a framed box clad like the house walls with a metal cap on top confirms it.
The firebox, pipe, spacers and cap were tested together and listed as one system. Brick, furnace cement or another maker's parts take it outside that listing, and that matters to a home inspector at a sale and to an insurer after a fire. So we order replacement parts by the model on the plate and fit them the way the manual shows.
Some parts, such as panels and screens, are still sold years after a model ends, and some are not. When a needed part is gone, we explain the options in writing: an insert listed for use in that firebox, a new factory-built unit framed into the same opening, or retiring the fireplace. Each comes with a price so you can compare.
For a yearly check of a fireplace that has not changed, a Level 1 at $55. A sale, a new appliance, a quake you felt or a chimney fire are the moments NFPA 211 ties to a Level 2, which costs $395 and adds video of the pipe and a look at the attic and chase. We tell you which one fits before booking.
Only when the video or the attic shows a sign of something hidden, such as scorched framing beside the pipe or a joint that has pulled apart out of camera reach. On a prefab system that can mean opening the chase wall or the ceiling where the pipe passes through. You see the scope, the openings and the patch work in writing before anything is cut.
Get everyone out of the house first, and leave switches, the fireplace remote and the valve alone on the way. Once outside, ring your gas utility or 911 from the street or a neighbor's porch. After the utility has made the line safe, we can come and look at the fireplace valve, fittings and pilot assembly.
Plan on it. A gas fireplace, a wood fireplace or a garage attached to the house each brings a home under California's carbon monoxide alarm law. For placement and type rules, ask the city building department. On our visits we note whether we saw a working alarm, but buying and mounting alarms is the owner's part.
Glendora sits inside the South Coast air district, which can declare no-burn days from November through February under its Rule 445. On those days wood fires are off for homes in its area, prefab wood fireplaces included, while gas fireplaces are not affected. The district posts each day's status on its website, so check it before you light a wood fire.
The usual suspect is the thermocouple or thermopile, the small sensor that sits in the pilot flame and tells the valve it may stay open. When it wears out or the flame stops reaching it, the valve closes. We test it with a meter before replacing anything, clean the pilot hood, and order the part by model if it has failed.
In a prefab house each fireplace normally has its own metal pipe, and two pipes may share one framed chase. Each pipe gets its own cap, sweep and inspection, so we price per fireplace. Brick houses can also carry more than one flue in a single stack, and we count them from the roof before quoting.
Brick repairs change too much from house to house: how many courses are loose, how tall the stack stands, whether the crown can stay. We see it, then put a price on each item in writing. The prices we do publish, like the $55 Level 1 and the sweep from $425, are for jobs that run the same on every house.
Glendora is home base. Azusa, Covina and Claremont make up most of our visits, and we also work in San Dimas, La Verne, West Covina, Duarte and Monrovia. Elsewhere in Los Angeles County, send the address through the contact page and we will confirm whether the house is on our route.
Out of Glendora

Azusa, Covina and Claremont close by, the foothill towns past them

Each of these 140 town pages says what kind of houses stand there and what their fireplaces tend to need. Type a name to jump to one.

House by house

Tract houses, foothill lots, older brick homes

The fireplace usually tells us when the house went up, and three kinds come up most on this route.

Metal box, framed chase

Tract houses from the 1970s on mostly carry a factory-built unit. Its plate tells us which panels, caps and chase top belong to it, and those are the parts we order.

Foothill lots

Houses up against the San Gabriel foothills see Santa Ana winds and brush fire seasons, so caps with intact mesh and chase tops without rust holes matter more there.

Older brick stacks

Postwar ranch homes often keep a brick chimney. Those get masonry work and a seismic look, because tall brick above a roof is what a quake tests first.

Metal Fireboxes and Chases

A cracked panel or a rusted top? Book a look from Glendora

The technician reads the plate, photographs what is worn, and leaves a written price for parts matched to your model. Phone, or describe the fireplace in the form.

(626) 557-0313

Booking calls taken every day of the week

Describe the fireplace

Where it is, wood or gas, and what it does.

By sending, you agree Tully Chimney Works may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

From Glendora to Your Living Room

Plate read, parts matched, price on paper

Tell us where the house is and what the fireplace is doing. The model number, the inspection and the written price are ours to sort out.

01

Send the address and the symptom

Use the form to say where the house is, whether the fireplace burns wood or gas, and what it is doing. If you can read a brand on the plate, add it.

02

We call back to book

We confirm which visit fits, the published price where there is one, and an arrival window that works for you.

03

Plate first, then parts

On site the technician finds the listing plate, records the model, then inspects or works through the parts that model uses.

04

Report and written price

You receive photos of each finding, a plain note on what it means for using the fireplace, and a price for any repair.

05

Parts by model, then the fix

Once you approve, we order the listed parts, come back to fit them, and add photos of the finished work to your report.

Call (626) 557-0313

Prefer writing? The contact page form reaches the same desk.

Call (626) 557-0313